Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
Rev. Cient. CRO-RJ (Online) ; 6(1): 26-33, abr. 2021.
Article in English | LILACS, BBO | ID: biblio-1354405

ABSTRACT

Objective: This study aimed to compare through cone-beam computed tomography (CBCT) the morphology of the cervical vertebrae atlas (C1) and axis (C2) in mouth breathers (MB) and nose breathers (NB), correlating them with the head and neck postures of the two groups. Materials and Methods: CBCT images of 36 subjects aged 11 to 22 years were evaluated using the InVivo Dental 5.1 (Anatomage, San Jose, California) software. The following measurements were used to assess C1 and C2 morphology: posterior height, anterior height, length, and volume. The craniocervical angle (NSL/OPT) was used to evaluate head posture concerning the neck. Results: The posterior height, length, and volume of C1 and C2 were lower in the MB group, but only the posterior size was significantly shorter than the NB group (C1, p=0.01 / C2, =0.05). Mouth breathers also showed a considerably higher craniocervical angle (p=0.04). Spearman test showed a significant positive correlation between C1 and C2 length and craniocervical angle (C1, =0.629, p=0.005 / C2, =0.665, p=0.003). Conclusion: The mouth breathers showed an increased craniocervical angle and decreased posterior height of the C1 vertebra concerning nasal breathers. The hyperextension of the head present is positively correlated with the length of the vertebra.


Objetivo: Este estudo teve como objetivo comparar por meio da tomografia computadorizada de feixe cônico (TCFC) a morfologia do atlas das vértebras cervicais (C1) e do eixo (C2) em respiradores orais (MB) e nasais (RN), correlacionando-os com a cabeça e posturas do pescoço dos dois grupos. Materiais e Métodos: Imagens de CBCT de 36 indivíduos com idades entre 11 e 22 anos foram avaliadas usando o software InVivo Dental 5.1 (Anatomage, San Jose, Califórnia). As seguintes medidas foram usadas para avaliar a morfologia de C1 e C2: altura posterior, altura anterior, comprimento e volume. O ângulo craniocervical (NSL/OPT) foi utilizado para avaliar a postura da cabeça em relação ao pescoço. Resultados: A altura posterior, comprimento e volume de C1 e C2 foram menores no grupo MB, mas apenas o tamanho posterior foi significativamente menor que o grupo RN (C1, p=0,01 / C2, =0,05). Os respiradores orais também apresentaram um ângulo craniocervical consideravelmente maior (p=0,04). O teste de Spearman mostrou correlação positiva significativa entre comprimento de C1 e C2 e ângulo craniocervical (C1, =0,629, p=0,005 / C2, =0,665, p=0,003). Conclusão: Os respiradores orais apresentaram aumento do ângulo craniocervical e diminuição da altura posterior da vértebra C1 em relação aos respiradores nasais. A hiperextensão da cabeça presente está positivamente correlacionada com o comprimento da vértebra.


Subject(s)
Dentistry , Cervical Atlas , Axis, Cervical Vertebra , Cone-Beam Computed Tomography , Mouth Breathing
2.
Dental press j. orthod. (Impr.) ; 26(3): e2119300, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1286207

ABSTRACT

ABSTRACT Introduction: In Orthodontics and Facial Orthopedics, the timing of treatment onset may be critical and individual analysis should be applied to promote a favorable treatment planning. In this study, individual analysis of midpalatal suture (MS) and palatal measurements were performed in teenagers and young adult patients treated with rapid maxillary expansion (RME). Description: Twenty-six patients submitted to RME with a tooth-supported appliance (Hyrax) were evaluated. The inclusion criteria were: minimum age of 14 years, presenting all posterior teeth, diagnosed with transverse maxillary discrepancy, and with a clinical indication for maxillary expansion. The pretreatment CBCT scans of these patients were assessed to obtain the stages of MS maturation (MSM); density ratio (MSD); and palatal length, thickness (anterior, intermediate and posterior) and sagittal area. Results: The maturation stages present were C, D or E; the density ranged from 0.6 to 1, and lower density (MSD < 0.75) and higher density (MSD ≥ 0.75) groups were determined. Individuals with higher MSD presented smaller sagittal area, compared to the lower density group. Individuals in D and E MSM stages presented smaller sagittal area and intermediate thickness, compared to stage C. Conclusions: Smaller palatal sagittal area was observed in the high MSD groups and in the stages D and E of MSM.


RESUMO Introdução: Em Ortodontia e Ortopedia Facial, o momento de início do tratamento pode ser crítico, e uma análise individual deve ser aplicada para promover um planejamento de tratamento favorável. No presente estudo, foram realizadas a avaliação individualizada da sutura palatina mediana (SPM) e medições no palato de adolescentes e adultos jovens tratados com expansão rápida da maxila (ERM). Descrição: Foram avaliados vinte e seis pacientes submetidos à ERM com aparelho dentossuportado (Hyrax). Os critérios de inclusão foram: idade mínima de 14 anos, apresentando todos os dentes posteriores, diagnosticado com discrepância transversa da maxila e com uma indicação clínica para expansão maxilar. A tomografia computadorizada de feixe cônico (TCFC) pré-tratamento desses pacientes foi avaliada para obter os estágios de maturação da SPM (MSPM), densidade da SPM (DSPM), comprimento do palato, espessura (anterior, intermediária e posterior) e área sagital. Resultados: Os estágios de maturação presentes foram C, D ou E; a densidade variou de 0,6 a 1, e foram determinados grupos de baixa (DSPM < 0,75) e alta densidade (DSPM ≥ 0,75). Indivíduos com maior DSPM apresentaram menor área sagital, em comparação com o grupo de densidade mais baixa. Indivíduos nos estágios D e E de MSPM apresentaram menor área sagital e espessura intermediária, comparados aos indivíduos no estágio C. Conclusão: Uma menor área sagital palatina foi observada nos grupos de alta DSPM e nos estágios D e E de MSPM.


Subject(s)
Humans , Male , Adolescent , Young Adult , Palatal Expansion Technique , Sexual and Gender Minorities , Sutures , Homosexuality, Male , Cranial Sutures/diagnostic imaging , Cone-Beam Computed Tomography , Maxilla/surgery , Maxilla/diagnostic imaging
3.
Dental press j. orthod. (Impr.) ; 26(2): e211955, 2021. tab
Article in English | LILACS, BBO | ID: biblio-1249701

ABSTRACT

ABSTRACT Objective: To assess the color of different orthodontic resin bonding agents exposed to three antiseptic mouthrinses for a prolonged time interval (10-year aging simulation). Methods: 160 specimens were distributed into four groups, according to the orthodontic resin bond agent (Concise, Transbond XT, Transbond Plus Color Change, and Natural Ortho). Each group was exposed to different antiseptic mouthrinses: alcohol-based (Listerine®), alcohol-free (Oral-B®), chlorhexidine (Periogard®) and distilled water as the control. Specimens were submitted to two cycles of staining and artificial aging. Color was evaluated by means of a digital spectrophotometer at the beginning of the experiment and after every cycle. The system used to assess color changes was the CIE L*a*b*. Data was analyzed using the ANOVA and Tukey post-hoc test. Results: After simulation of 10 years of aging, Transbond XT and Natural Ortho composites presented no statistically significant differences in ∆E when exposed to different mouthrinses. The Concise composite specimens exposed to alcohol-free mouthrinse presented a significant difference when compared with specimens from the same group exposed to other antiseptic mouthrinses. Transbond Plus Color Change specimens exposed to chlorhexidine mouthrinse and to alcohol-containing mouthrinse presented a significant difference when compared with the specimens from the group exposed to water and alcohol-free antiseptic. Conclusion: All orthodontic resin bonding agents tested presented clinically perceptible color changes when exposed to at least one of the mouthrinses, except for the Natural Ortho composite. The Concise composite exposed to the alcohol-free solution was the resin that presented the highest color change values.


RESUMO Objetivo: Avaliar a cor de diferentes resinas ortodônticas expostas a três enxaguantes bucais, por um intervalo de tempo prolongado (simulação de 10 anos de envelhecimento). Métodos: 160 espécimes foram distribuídos em quatro grupos, de acordo com a resina de colagem ortodôntica (Concise, Transbond XT, Transbond Plus Color Change e Natural Ortho). Cada grupo foi exposto a diferentes tipos de enxaguantes bucais: à base de álcool (Listerine®), isento de álcool (Oral-B®), clorexidina (Periogard®) ou água destilada, como controle. Os espécimes foram submetidos a dois ciclos de manchamento e envelhecimento artificial. A cor foi avaliada por meio de um espectrofotômetro digital no início do experimento e após cada ciclo. O sistema utilizado para avaliar as alterações de cor foi o CIE L*a*b*. Os dados foram analisados utilizando-se o teste ANOVA e o teste post-hoc de Tukey. Resultados: Após a simulação de 10 anos de envelhecimento, as resinas Transbond XT e Natural Ortho não apresentaram diferenças estatisticamente significativas no ∆E, quando expostas a diferentes enxaguantes bucais. Os espécimes do grupo Concise expostos ao enxaguante bucal sem álcool apresentaram diferença significativa quando comparados aos espécimes do mesmo grupo expostos aos outros enxaguantes bucais. Os espécimes do grupo Transbond Plus Color Change expostos à clorexidina e ao enxaguante bucal à base de álcool apresentaram diferença significativa quando comparados aos espécimes dos grupos expostos à água e ao enxaguante bucal sem álcool. Conclusão: Todas as resinas ortodônticas avaliadas apresentaram alterações de cor clinicamente perceptíveis quando expostas a pelo menos um dos enxaguantes bucais, com exceção da resina ortodôntica Natural Ortho. A resina Concise exposta à solução isenta de álcool foi a que apresentou os maiores valores de alteração de cor.


Subject(s)
Chlorhexidine , Orthodontic Brackets , Composite Resins , Anti-Infective Agents, Local , Materials Testing , Resin Cements , Mouthwashes
4.
Rev. Cient. CRO-RJ (Online) ; 5(2): 36-42, May-Aug. 2020.
Article in English | BBO, LILACS | ID: biblio-1253974

ABSTRACT

Introduction: Excess of adhesive around brackets negatively impact oral health of orthodontic patients. Objective: Evaluate the influence of orthodontic bonding system in removal of adhesive flash around orthodontic brackets. Methods: Based on their characteristics, four orthodontic bonding systems were selected: lightcuring adhesive (G1 - TransbondTM XT); pink pigmented light-curing adhesive (G2- TransbondTM Plus Color Change); resin-modified glass ionomer cement (G3 - FujiOrthoTM LC); and auto-curing adhesive (G4 - ConciseTM). For each group (n=10), a single operator placed metal brackets on bovine teeth (n=40) and used an explorer tip to visually remove flash excess. After curing / setting, the sampleswere taken to a stereomicroscope and the Axio Vision 4.4 software was used to measure the area of remnant adhesive flash around each bracket. The quantitative data obtained was analyzed by the Kruskal-Wallis and Dunn's post hoc test at = 0.05. Results: The results show that the resin-modified glass ionomer cement (G3) had a larger area of remnant material than the other groups. There was no statistical difference between the other groups (G1, G2, and G4), independently of pigmentation or curing technique. Conclusion: It was concluded that the use of a resin-modified glass ionomer cement results in a larger area of remnant flash excess, which can negatively impact oral health. Pigmentation and curing technique did not influence on remnant flash excess.


Introdução: O excesso de material de colagem que permanece ao redor dos bráquetes impacta negativamente a saúde bucal dos pacientes ortodônticos. Objetivo: Avaliar a influência dos sistemas de colagem ortodônticos na remoção de excesso de adesivo ao redor de bráquetes. Métodos: Baseado em suas características, quatro sistemas de colagem ortodônticos foram selecionados: adesivo fotopolimerizável (G1 ­ TransbondTM XT); adesivo fotopolimerizável com pigmentação rosa (G2 - TransbondTM Plus Color Change); cimento de ionômero de vidro reforçado com resina (G3 - FujiOrthoTM LC); e adesivo autopolimerizável (G4 - ConciseTM). Para cada grupo (n=10), um único operador posicionou os bráquetes em dentes bovinos (n=40) e utilizou uma sonda exploradora para remoção visual do excesso de material de colagem. Após a polimerização / tempo de cura, as amostras foram levadas ao estereomicroscópio e o software Axio Vision 4,4 foi utilizado para mensurar a área de excesso de adesivo remanescente ao redor de cada bráquete. Os dados quantitativos obtidos foram analisados pelos testes de Kruskal-Wallis e post-hoc de Dunn em significância de = 0,05. Resultados: O cimento de ionômero de vidro reforçado por resina (G3) apresentou a maior área de remanescente de excesso. Não houve diferença estatisticamente significativa entre os demais grupos (G1, G2 e G4), independente da pigmentação ou do método de polimerização. Conclusão: O uso de cimento de ionômero de vidro reforçado por resina resulta em maior área de excesso remanescente, o que pode impactar negativamente a saúde bucal. A pigmentação e o método de polimerização não influenciaram no excesso de material remanescente.


Subject(s)
Orthodontics , Oral Health , Dental Bonding , Orthodontic Brackets
5.
Dental press j. orthod. (Impr.) ; 24(5): 60-68, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1039665

ABSTRACT

ABSTRACT Objective: To assess the volume and morphology of the middle region of the pharynx (MRP) in adolescents with different anteroposterior craniofacial skeletal patterns. Methods: One hundred twenty-six patients (56 male and 70 female), who had cone-beam computed tomography (CBCT) within their records, were selected for this cross-sectional study. Participants were classified, according to their ANB angle value, in Class I (1o ≤ ANB ≤ 3o), Class II (ANB > 3o) and Class III (ANB < 1o). The total volume (tV), minimum axial area (AxMin) and morphology of the MRP and its subdivisions - velopharynx (VP) and oropharynx (OP) - were characterized by CBCT and 3-dimensional image reconstruction software. Intergroup comparisons were performed by ANOVA and Tukey post-hoc tests. Correlations between tV and Axmin with the ANB angle values were tested using linear regression analysis, considering sex as covariable. Results: Statistically significant difference between groups were observed in tV only for the VP region; Class II individuals presented significantly lower tV (6863.75 ± 2627.20 mm3) than Class III subjects (9011.62 ± 3442.56 mm3) (p< 0.05). No significant differences were observed between groups for any other variable assessed, neither in MRP nor in the OP region (p> 0.05). A significant negative correlation was evidenced between tV and Axmin and the ANB angle values; sexual dimorphism was observed for some variables. Conclusions: Class II subjects have smaller tV in the VP region. tV and Axmin tend to decrease in all evaluated regions when the ANB angle values increase.


RESUMO Objetivo: avaliar o volume e a morfologia da porção média da faringe (PMF) em adolescentes com diferentes padrões esqueléticos no sentido anteroposterior. Método: para esse estudo transversal, foram selecionados cento e vinte e seis pacientes (56 homens e 70 mulheres) que tinham tomografia computadorizada de feixe cônico (TCFC) em seus registros. Os participantes foram classificados de acordo com o valor do ângulo ANB, em Classe I (1o ≥ ANB ≤ 3o), Classe II (ANB > 3o) e Classe III (ANB < 1o). O volume total (Vt), a área axial mínima (AxMin) e a morfologia da PMF e de suas subdivisões - velofaringe (VF) e orofaringe (OF) - foram avaliados na TCFC e em software de reconstrução tridimensional (3D) de imagens. As comparações intergrupos foram realizadas por meio dos testes ANOVA e post-hoc de Tukey. As correlações entre os valores de Vt e Axmin das vias aéreas com os valores do ângulo ANB foram testadas por meio de análise de regressão linear, considerando-se o sexo como uma covariável. Resultados: diferença estatisticamente significativa entre os grupos foi observada apenas no Vt da VF; indivíduos Classe II apresentaram Vt significativamente menor (6.863,75 ± 2.627,20 mm3) do que indivíduos Classe III (9.011,62 ± 3.442,56 mm3) (p< 0,05). Não foram observadas diferenças significativas entre os grupos em nenhuma outra variável avaliada, nem na PMF, nem na OF (p> 0,05). Foi evidenciada uma correlação negativa significativa entre Vt e Axmin e os valores do ângulo ANB; dimorfismo sexual foi observado para algumas variáveis. Conclusões: indivíduos Classe II apresentam o menor Vt da VF. O Vt e a Axmin tenderam a diminuir quando os valores do ângulo ANB aumentaram, em todas as regiões avaliadas.


Subject(s)
Humans , Male , Female , Adolescent , Pharynx , Malocclusion, Angle Class III , Cephalometry , Cross-Sectional Studies , Imaging, Three-Dimensional , Cone-Beam Computed Tomography , Mandible
6.
Rev. Cient. CRO-RJ (Online) ; 4(3): 10-16, 2019.
Article in English | BBO, LILACS | ID: biblio-1052180

ABSTRACT

Objective: To compare the facial soft tissues of nasal breathers (NB) and mouthbreathers (MB) using cone-beam computed tomography (CBCT).Methods: This was a comparative study of four angular and eight linearcephalometric variables obtained from the facial soft tissues of 43 young menand women aged between 11 and 24 years. Subjects had tomographic examinationprior to the orthodontic treatment and were previously divided into two groupsby an otolaryngologist according to the respiratory pattern of nasal or mouthbreathing. The selection was made in accordance with the results of: clinicalexamination, rhinoscopy, and nasal endoscopy. The data obtained from thesoftware InVivo Dental 5.3 (Anatomage - San Jose, California) was evaluated bycomparing values measured between MB and NB groups. Results: There weresignificant differences between groups for variables, "nasolabial angle", inclinationof upper central incisor" and "convexity of the facial soft tissues". Conclusion:Adolescent and young adult mouth breathers present an open nasolabial angledue to the retroinclination of their upper incisors. In addition to greater convexityof the facial soft tissues.


Objetivo: Comparar os tecidos moles faciais de respiradores nasais (RN) e bucais(RB), utilizando imagens de tomografia computadorizada de feixe cônico (TCFC).Métodos: Foi realizado um estudo comparativo composto por quatro variáveiscefalométricas angulares e oito lineares, obtidas de tecidos moles faciais deindivíduos RN e RB, em uma amostra composta por 43 indivíduos jovens deambos os sexos, com idades entre 11 e 24 anos, submetidos ao exame tomográficoanteriormente ao tratamento ortodôntico. Os indivíduos foram previamentedivididos em dois grupos por um otorrinolaringologista, de acordo com o padrãorespiratório. O diagnóstico da respiração bucal foi feito em conformidade comos resultados de exames específicos: exame clínico, rinoscopia e endoscopia nasal.Os dados obtidos a partir do software InVivo 5.3 Dental (Anatomage - San Jose,Califórnia) foram avaliados através da comparação dos valores das mediçõesdas variáveis dos grupos RN e RB, além da comparação das diferenças entreesses valores. Resultados: Houve diferenças estatisticamente significativas entreos grupos com relação às variáveis, "ângulo nasolabial", "inclinação do incisivocentral superior" e "convexidade dos tegumentos faciais". Conclusão: Osrespiradores bucais adolescentes e adultos jovens apresentam ângulo nasolabialmais aberto, devido à maior inclinação lingual do longo eixo dos incisivossuperiores, além de maior convexidade dos tecidos moles faciais.


Subject(s)
Orthodontics , Nasal Obstruction , Cephalometry , Adolescent , Cone-Beam Computed Tomography , Young Adult , Mouth Breathing
7.
Rev. Cient. CRO-RJ (Online) ; 4(3): 32-36, 2019.
Article in English | BBO, LILACS | ID: biblio-1052239

ABSTRACT

Objective: Our aim wasto analyze the reliability of midpalatal suture maturationassessment in females in the final growth period using cone-beam computedtomography (CBCT) by an undergraduate student in two time periods (intra-examiner) and compared to an orthodontist (inter-examiner). Methods: Fortypretreatment CBCT images of 14 to 19-year-old females were selected. Imageswere oriented in the InVivo Dental 5.1 software. Axial slices were selected either bya researcher (preselected slices ­ suture-PS) or by the examiners (free scanningand slice selection ­ suture-FS) and each image was classified according to itsmidpalatal suture maturation stage. The examiners analyzed all imagesindividually and twice, with a two-week interval between sessions. The weightedkappa coefficient according to Landis and Kock was used to assess intra- andinter-examiner agreement. Results: The Kappa intra-examiner of theundergraduate student was 0.824 for suture-PS and 0.692 for suture-FS, and theorthodontist was 0.919 and 0.695, respectively. Inter-observer agreement washigher for suture-PS (>0.479) than for suture-FS (>0.300). Conclusion: The intra-observer kappa coefficient was very good for the undergraduate student, similarto the orthodontist. However, inter-examiner agreement was not good, indicatinga need for development in the method training.


Objetivo: Avaliar a confiabilidade da classificação dos estágios de fusão da suturapalatina mediana em adolescentes do sexo feminino através de tomografiacomputadorizada cone beam (TCCB) por aluno da graduação em dois tempos(intraexaminador) e comparado a um ortodontista (interexaminador). Métodos:Foram selecionadas tomografias de 40 meninas na faixa etária de 14 a 19 anos feitaspreviamente ao tratamento ortodôntico. No software InVivo Dental 5.1 as imagens dacabeça foram orientadas de forma padronizada. Os cortes axiais desejados foramselecionados por um pesquisador ou por cada examinador e cada imagemresultante foi classificada quanto ao estágio de fusão da sutura palatina mediana.Os operadores realizaram todas as classificações duas vezes com intervalo de duassemanas entre as sessões, cada um individualmente. O coeficiente kappa ponderadode acordo com Landis e Kock foi utilizado para avaliar a concordânciaintraexaminador e interexaminador. Resultados: O kappa intraexaminador doaluno da graduação foi de 0,824 pra cortes pré-selecionados e 0,692 para osorientados por ele mesmo, e do ortodontista foi de 0,919 e 0,695, respectivamente.O coeficente kappa entre eles foi 0,479 e 0,300. Conclusão: Apesar do aluno degraduação ser mais inexperiente, sua concordância intraexaminador foi muitoboa, semelhante à do ortodontista. No entanto, a concordância entre eles não foiboa, demonstrando necessidade de aprimoramento no treinamento do método.


Subject(s)
Diagnostic Imaging , Palatal Expansion Technique , Adolescent , Palate, Hard , Cone-Beam Computed Tomography
8.
Braz. oral res. (Online) ; 32: e30, 2018. tab, graf
Article in English | LILACS | ID: biblio-889460

ABSTRACT

Abstract Botulinum toxin type A is effective in reducing excessive gingival display caused by hyperfunctional upper lip elevator muscles; however, this effect is transient. This study aimed to determine the duration of the effectiveness of botulinum toxin type A on a gummy smile. A systematic search was conducted using Medline (PubMed), Scopus, and Web of Science electronic databases, from 1970 to March 2017 with no language restriction; the search included studies evaluating adult patients with excessive gingival display who were treated with botulinum toxin and were followed-up for at least 3 months. OpenGrey and Clinical Trial Registry were also consulted. Quality assessment was applied to determine the level of evidence and bias, and a meta-analysis was performed. Of 2181 full texts, 71 were obtained, with 3 prospective studies meeting the selection criteria. The gingival display was significantly reduced to baseline with 2, 4, and 8 weeks of treatment. The gingival display considerably reduced at the baseline-2-week comparison (-4.44 mm using raw data and-4.05 mm using the standard difference) and increased throughout the weeks of follow-up. There is scant evidence to determine the duration of the effectiveness of toxin type A on a gummy smile. The effect tends to be stable until at least 8 weeks of follow-up, and the gingival exposure may not return to baseline within 12 weeks of follow-up. Well-designed randomized clinical trials with a minimum of 6 months of follow-up are necessary to strengthen the evidence.


Subject(s)
Humans , Botulinum Toxins, Type A/therapeutic use , Gingiva/drug effects , Neuromuscular Agents/therapeutic use , Smiling , Esthetics, Dental , Facial Muscles/drug effects , Gingiva/pathology , Reproducibility of Results
9.
Dental press j. orthod. (Impr.) ; 22(2): 35-44, Mar.-Apr. 2017. tab, graf
Article in English | LILACS | ID: biblio-840217

ABSTRACT

ABSTRACT OBJECTIVE: The aim of this systematic review was to evaluate the duration of the retention period in growing patients undergoing maxillary expansion and its relation with posterior crossbite stability. METHODS: Search strategies were executed for electronic databases Cochrane Library, Web of Science, PubMed and Scopus, which were completed on January 15, 2016. The inclusion criteria included randomized, prospective or retrospective controlled trials in growing subjects with posterior crossbite; treated with maxillary expanders; retention phase after expansion; post-retention phase of at least 6 months. The exclusion criteria were anterior crossbite, craniofacial anomalies, surgery or another orthodontic intervention; case reports; author’s opinions articles, thesis, literature reviews and systematic reviews. The risk of bias of selected articles was assessed with Cochrane risk of bias tool for RCTs and Downs and Black checklist for non-RCTs. RESULTS: A total of 156 titles/abstracts was retrieved, 44 full-texts were examined, and 6 articles were selected and assessed for their methodological quality. The retention period after maxillary expansion ranged between 4 weeks and 16 months. Fixed (acrylic plate, Haas, Hyrax and quad-helix) or removable (Hawley and Hawley expander) appliances were used for retention. CONCLUSIONS: Six months of retention with either fixed or removable appliances seem to be enough to avoid relapse or to guarantee minimal changes in a short-term follow-up.


RESUMO OBJETIVO: o objetivo da presente revisão sistemática foi avaliar a duração do período de contenção e a estabilidade do tratamento ortodôntico com expansão maxilar em pacientes em crescimento com mordida cruzada posterior. MÉTODOS: foram realizadas buscas estratégicas nas bases eletrônicas: Cochrane Library, Web of Science, PubMed e Scopus, até 15 de janeiro de 2016. Os critérios de inclusão foram: estudos clínicos controlados e randomizados, prospectivos ou retrospectivos, de pacientes em crescimento com mordida cruzada; tratados com aparelhos expansores maxilares, com fase de contenção pós-expansão e no mínimo seis meses de fase de pós-contenção. Os critérios de exclusão foram: mordida cruzada anterior, anomalias craniofaciais, cirurgia ou outro tratamento ortodôntico; relato de casos; artigos de opinião; teses; revisões de literatura e revisões sistemáticas. O risco de viés dos artigos selecionados foi avaliado a partir do Cochrane risk of bias tool para ensaios clínicos randomizados e Downs and Black checklist para ensaios clínicos não randomizados. RESULTADOS: a busca resultou em 156 títulos/resumos, sendo 44 textos examinados na íntegra. Foram selecionados 6 artigos para o acesso à qualidade metodológica. A duração do período de contenção ocorreu entre 4 semanas e 6 meses. Aparelhos fixos (aparelho em acrílico, Haas, Hyrax e quad-helix) ou removíveis (Hawley e Hawley com expansor) foram utilizados na fase de contenção. CONCLUSÃO: parece que seis meses de contenção com aparelhos fixos ou removíveis são suficientes para evitar a recidiva ou garantir mudanças mínimas em um curto período de acompanhamento pós-contenção.


Subject(s)
Humans , Palatal Expansion Technique/instrumentation , Malocclusion/therapy , Orthodontics, Corrective , Recurrence , Randomized Controlled Trials as Topic , Databases, Factual , Orthodontic Retainers
10.
Braz. oral res. (Online) ; 31: e68, 2017. tab, graf
Article in English | LILACS | ID: biblio-952108

ABSTRACT

Abstract The objective of this study was to compare coating dimensions and surface characteristics of two different esthetic covered nickel-titanium orthodontic rectangular archwires, as-received from the manufacturer and after oral exposure. The study was designed for comparative purposes. Both archwires, as-received from the manufacturer, were observed using a stereomicroscope to measure coating thickness and inner metallic dimensions. The wires were also exposed to oral environment in 11 orthodontic active patients for 21 days. After removing the samples, stereomicroscopy images were captured, coating loss was measured and its percentage was calculated. Three segments of each wire (one as-received and two after oral exposure) were observed using scanning electron microscopy for a qualitative analysis of the labial surface of the wires. The Lilliefors test and independent t-test were applied to verify normality of data and statistical differences between wires, respectively. The significance level adopted was 0.05. The results showed that the differences between the wires while comparing inner height and thickness were statistically significant (p < 0.0001). In average, the most recently launched wire presented a coating thickness twice that of the control wire, which was also a statistically significant difference. The coating loss percentage was also statistically different (p = 0.0346) when the latest launched wire (13.27%) was compared to the control (29.63%). In conclusion, the coating of the most recent wire was thicker and more uniform, whereas the control had a thinner coating on the edges. After oral exposure, both tested wires presented coating loss, but the most recently launched wire exhibited better results.


Subject(s)
Humans , Orthodontic Wires , Titanium/chemistry , Orthodontic Appliance Design , Coated Materials, Biocompatible/chemistry , Nickel/chemistry , Reference Values , Surface Properties , Time Factors , Materials Testing , Microscopy, Electron, Scanning , Orthodontic Brackets , Esthetics, Dental , Mouth/chemistry
11.
Dental press j. orthod. (Impr.) ; 21(5): 82-89, Sept.-Dec. 2016. tab, graf
Article in English | LILACS | ID: biblio-828656

ABSTRACT

ABSTRACT Objective: The aim of this preliminary study was to assess changes in tooth length and alveolar thickness following retraction of maxillary incisors. Methods: A total of 11 patients presenting severe maxillary dentoalveolar protrusion revealed by initial (T1) cone-beam computed tomography (CBCT), and whose treatment plan included extraction of maxillary first premolars and retraction of maxillary incisors, were selected and submitted to CBCT examination one month after the end of incisors retraction (T2). The premaxilla was assessed through seven axial slices by means of Dolphin ImagingTM software. In each of these slices, five measurements of the distance from the buccal cortical bone to the palatal cortical bone were performed. Tooth length of maxillary incisors (n = 44) was also measured in sagittal slices. Measurements were repeated after a two-week interval, and intraclass correlation coefficient (ICC) was used to test examiner calibration. Wilcoxon test was used to detect differences in measurements performed at the two time intervals. Results: The ICC was satisfactory for tooth length (0.890) and for premaxilla alveolar thickness measurements (0.980). Analysis of data showed no statistically significant differences (p > 0.05) in tooth length or alveolar thickness between the two-time intervals assessed. Conclusion: The force used in retraction of maxillary incisors in this research did not promote significant changes in tooth length of maxillary incisors or in premaxilla alveolar thickness.


RESUMO Objetivo: o objetivo deste estudo preliminar foi avaliar as alterações no comprimento dentário e na espessura alveolar durante a retração dos incisivos superiores. Métodos: um total de 11 pacientes apresentando protrusão dentoalveolar severa, de acordo com a tomografia computadorizada de feixe cônico (TCFC) inicial (T1), e que continham no seu plano de tratamento extração dos pré-molares superiores e retração dos incisivos superiores, foram selecionados e submetidos a exames de TCFC um mês após o término da retração dos incisivos (T2). Com o auxílio do software Dolphin Imaging(r), a prémaxila foi dividida em sete cortes axiais. Em cada corte axial, foram realizadas cinco medições da distância da cortical vestibular a lingual. O comprimento dos incisivos superiores (n = 44) foi medido no corte sagital. As medições foram refeitas após o intervalo de duas semanas e o coeficiente de correlação intraclasse (ICC) foi utilizado para avaliar a calibração do examinador. Utilizou-se o teste de Wilcoxon para detectar diferenças nas medições realizadas nos dois intervalos de tempo. Resultados: o ICC mostrou-se satisfatório tanto para o comprimento dentário (0,890) quanto para a espessura alveolar da pré-maxila (0,980). Não foram observadas diferenças estatísticas significativas para comprimento dentário e para as espessuras alveolares (p < 0,05) nos períodos avaliados. Conclusões: as forças atuantes na retração dos incisivos, nessa pesquisa, não provocaram alterações significativas no comprimento dentário dos incisivos superiores, nem mudanças na espessura alveolar da pré-maxila.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Young Adult , Root Resorption , Tooth Movement Techniques , Incisor/anatomy & histology , Tooth Extraction , Bicuspid/surgery , Prospective Studies , Cone-Beam Computed Tomography , Alveolar Process/anatomy & histology , Incisor/physiology , Incisor/diagnostic imaging , Malocclusion, Angle Class I/therapy , Malocclusion, Angle Class I/diagnostic imaging , Malocclusion, Angle Class II/therapy , Malocclusion, Angle Class II/diagnostic imaging , Maxilla
12.
Dental press j. orthod. (Impr.) ; 20(5): 35-42, tab, graf
Article in English | LILACS | ID: lil-764538

ABSTRACT

Objective: To compare in vivo orthodontic mini-implants (MI) of smooth (machined) and rough (acid etched) surfaces, assessing primary and secondary stability.Methods:Thirty-six (36) MI were inserted in the mandibles of six (6) dogs. Each animal received six (6) MI. In the right hemiarch, three (3) MI without surface treatment (smooth) were inserted, whereas in the left hemiarch, another three (3) MI with acid etched surfaces (rough) were inserted. The two distal MI in each hemiarch received an immediate load of 1.0 N for 16 weeks, whereas the MI in the mesial extremity was not subject to loading. Stability was measured by insertion and removal torque, initial and final mobility and by inter mini-implant distance.Results:There was no statistical behavioral difference between smooth and rough MI. High insertion torque and reduced initial mobility were observed in all groups, as well as a reduction in removal torques in comparison with insertion torque. Rough MI presented higher removal torque and lower final mobility in comparison to smooth MI. MI did not remain static, with displacement of rough MI being smaller in comparison with smooth MI, but with no statistical difference.Conclusions:MI primary stability was greater than stability measured at removal. There was no difference in stability between smooth and rough MI when assessing mobility, displacement and insertion as well as removal torques.


Objetivo: comparar, in vivo, mini-implantes (MI) com superfície lisa (usinada) e porosa (tratada com ácido), avaliando sua estabilidade primária e secundária.Métodos:trinta e seis MI foram inseridos na mandíbula de seis cães, e cada animal recebeu seis MI. Na hemiarcada direita, foram inseridos três MI sem tratamento da superfície (liso); na esquerda, outros três com a superfície tratada com ácido (poroso). Os dois MI distais de cada hemiarcada receberam carga imediata de 1,0N durante dezesseis semanas, e o MI da extremidade mesial não recebeu carregamento. A estabilidade foi medida pelos torques de inserção e de remoção, pela mobilidade inicial e final, e pela distância inter-MI.Resultados:não houve diferença estatística do comportamento entre os MI lisos e porosos. No entanto, observou-se torque de inserção elevado e mobilidade inicial reduzida em todos os grupos. Para todos os grupos, houve redução dos torques de remoção, em relação ao de inserção. Os MI porosos apresentaram maior torque de remoção e menor mobilidade final, em relação aos MI lisos. Os MI não permaneceram estáticos, sendo o deslocamento dos MI porosos menor em relação aos MI lisos, mas sem diferença estatística.Conclusões:a estabilidade primária dos MI foi maior do que a estabilidade medida na sua remoção; não houve diferença na estabilidade entre os MI lisos e porosos ao avaliar-se a mobilidade, o deslocamento e os torques de inserção e remoção.


Subject(s)
Animals , Male , Dogs , Surface Properties , Osseointegration , Dental Implants, Single-Tooth , Dental Implantation, Endosseous/instrumentation , Titanium , Dental Restoration Failure/statistics & numerical data , Torque , Dental Implantation, Endosseous/methods , Dental Stress Analysis/methods , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Immediate Dental Implant Loading/instrumentation , Metallurgy/methods
13.
Dental press j. orthod. (Impr.) ; 20(3): 88-95, May-Jun/2015. tab, graf
Article in English | LILACS | ID: lil-751411

ABSTRACT

OBJECTIVE: The aim of this study was to assess the regional influence on the perception of facial profile esthetics in Rio de Janeiro state (RJ) and Rio Grande do Sul state (RS), Brazil. METHODS: Two Caucasian models, a man and a woman, with balanced facial profiles, had their photographs digitally manipulated so as to produce seven different profiles. First year dental students (laypeople) assessed the images and classified them according to their esthetic preference. RESULTS: The result of the t test for independent samples showed differences among states for certain facial profiles. The female photograph identified with the letter 'G' (mandibular retrusion) received higher scores in RS state (p = 0.006). No differences were found for male photographs (p > 0.007). The evaluators' sex seemed not to influence their esthetic perception (p > 0.007). Considering all evaluators together, ANOVA/Tukey's test showed differences among the profiles (p ≤ 0.05) for both male and female photographs. The female photograph that received the highest score was the one identified with the letter 'F' (dentoalveolar bimaxillary retrusion/ straight profile). For the male profiles, photograph identified with the letter 'E' (dentoalveolar bimaxillary protrusion/ straight profile) received the best score. CONCLUSION: Regional differences were observed regarding preferences of facial profile esthetics. In Rio de Janeiro state, more prominent lips were preferred while in Rio Grande do Sul state, profiles with straight lips were favored. Class III profiles were considered less attractive. .


OBJETIVO: o objetivo desse estudo foi avaliar a influência regional na percepção da estética do perfil facial nos estados do Rio de Janeiro (RJ) e Rio Grande do Sul (RS), Brasil. MÉTODOS: dois modelos leucodermas, um homem e uma mulher, com perfis faciais harmoniosos, tiveram suas fotografias de perfil editadas de modo a produzir sete perfis diferentes. As imagens foram avaliadas por estudantes do primeiro ano do curso de Odontologia (leigos), que as classificaram quanto à sua preferência estética. RESULTADOS: o resultado do teste t para amostras independentes demonstrou haver diferença entre as regiões, quanto à preferência estética de determinados perfis faciais. A fotografia feminina nomeada com a letra 'G' (retrusão da mandíbula) recebeu os maiores escores em RS (p = 0,006). Para as fotografias masculinas, não houve diferença (p > 0,007). O sexo dos avaliadores não exerceu influência na percepção da estética do perfil (p > 0,007). Considerando todos os avaliadores em conjunto, o teste ANOVA/Tukey mostrou haver diferença entre os perfis avaliados (p ≤ 0,05) tanto para as fotografias femininas quanto para as masculinas. A fotografia feminina preferida foi a com a letra 'F' (biretrusão dentoalveolar/perfil reto). A fotografia masculina preferida foi a 'E' (biprotrusão dentoalveolar/perfil reto). CONCLUSÃO: foi observada diferença regional quanto à preferência estética do perfil. No estado do Rio de Janeiro, houve preferência por lábios mais proeminentes; enquanto no estado do Rio Grande do Sul, os perfis considerados mais atrativos foram os retos. Os perfis considerados menos atrativos foram os que correspondem à Classe III. .


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Esthetics , Face/anatomy & histology , Beauty , Brazil/ethnology , Photography/methods , Attitude , Sex Factors , Cephalometry/methods , Black People/psychology , White People/psychology , Mandible/anatomy & histology , Maxilla/anatomy & histology
14.
Dental press j. orthod. (Impr.) ; 20(2): 29-34, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-745854

ABSTRACT

OBJECTIVE: The purpose of this study was to assess the influence of magnification and superimposition of structures on CBCT-generated lateral cephalometric radiographs (LCR) using different segments of the cranium. METHODS: CBCT scans of 10 patients were selected. Four LCR were generated using Dolphin Imaging(r) software: full-face, right side, left side and center of the head. A total of 40 images were imported into Radiocef Studio 2(r), and the angles of the most common cephalometric analyses were traced by the same observer twice and within a 10-day interval. Statistical analyses included intraexaminer agreement and comparison between methods by means of intraclass correlation coefficient (ICC) and Bland-Altman agreement tests. RESULTS: Intraexaminer agreement of the angles assessed by ICC was excellent (> 0.90) for 83% of measurements, good (between 0.75 and 0.90) for 15%, and moderate (between 0.50 and 0.75) for 2% of measurements. The comparison between methods by ICC was excellent for 68% of measurements, good for 26%, and moderate for 6%. Variables presenting wider confidence intervals (> 6o) in the Bland-Altman tests, in intraexaminer assessment, were: mandibular incisor angle, maxillary incisor angle, and occlusal plane angle. And in comparison methods the variables with wider confidence interval were: mandibular incisor, maxillary incisor, GoGn, occlusal plane angle, Frankfort horizontal plane (FHP), and CoA. CONCLUSION: Superimposition of structures seemed to influence the results more than magnification, and neither one of them significantly influenced the measurements. Considerable individual variability may occur, especially for mandibular and maxillary incisors, FHP and occlusal plane. .


OBJETIVO: o objetivo do presente estudo foi avaliar a influência da sobreposição estrutural e da magnificação nas radiografias cefalométricas laterais (RCL) geradas por meio de tomografias computadorizadas de feixe cônico (TCFC), usando diferentes segmentos do crânio. MÉTODOS: foram selecionadas 10 tomografias de pacientes. Quatro RCL foram geradas usando Dolphin Imaging, sendo face total, lado direito, lado esquerdo e o centro da cabeça. Um total de 40 imagens foi importado para o Radiocef Studio, e os ângulos das análises cefalométricas mais comuns foram medidos pelo mesmo observador, duas vezes, em um intervalo de 10 dias. As análises estatísticas incluíram concordância intraexaminador e comparação entre os métodos por meio do coeficiente de correlação intraclasse (ICC) e testes de concordância de Bland-Altman. RESULTADOS: a concordância intraexaminador dos ângulos avaliados pelo ICC foi excelente (> 0,90) para 83% das medições, boa (entre 0,75 e 0,90) para 15%, e moderada (entre 0,50 e 0,75) para 2% das medições. A comparação entre os métodos por ICC foi excelente para 68% das medições, boa para 26% e moderada para 6%. As variáveis que apresentaram intervalos de confiança mais amplos (> 6°) nos testes de Bland-Altman, na avaliação intraexaminador, foram: incisivo superior, incisivo inferior e plano oclusal, enquanto nos métodos de comparação, as variáveis com intervalos de confiança mais amplos foram: incisivo inferior, incisivo superior, GoGn, ângulo do plano oclusal, plano horizontal de Frankfort e CoA. CONCLUSÃO: a sobreposição estrutural pareceu influenciar os resultados mais do que a magnificação, mas os métodos não influenciaram significativamente as medições. Considerável variabilidade individual pode ocorrer especialmente para os incisivos superiores e inferiores, plano horizontal de Frankfort e plano oclusal. .


Subject(s)
DNA Repair , Deoxyguanosine/analogs & derivatives , Escherichia coli Proteins/genetics , Escherichia coli/genetics , Gene Expression Regulation, Bacterial , Mutagenesis/radiation effects , Sugar Acids/metabolism , Biological Assay , DNA Breaks, Double-Stranded , DNA Polymerase beta/genetics , DNA Polymerase beta/metabolism , Deoxyguanosine/chemistry , Deoxyguanosine/metabolism , Escherichia coli Proteins/metabolism , Escherichia coli/metabolism , Escherichia coli/radiation effects , Flap Endonucleases/genetics , Flap Endonucleases/metabolism , Furans/chemistry , Furans/metabolism , Gamma Rays , Mutation , Plasmids , Sugar Acids/chemistry
15.
Dental press j. orthod. (Impr.) ; 20(1): 66-73, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-741440

ABSTRACT

OBJECTIVE: To determine by means of a systematic review the best treatment, whether interproximal wear or incisor extraction, to correct anterior lower crowding in Class I patients in permanent dentition. METHODS: A literature review was conducted using MEDLINE, Scopus and Web of Science to retrieve studies published between January 1950 and October 2013. In selecting the sample, the following inclusion criteria were applied: studies involving interproximal wear and/or extraction of mandibular incisors, as well as Class I cases with anterior lower crowding in permanent dentition. RESULTS: Out of a total of 943 articles found after excluding duplicates, 925 were excluded after abstract analysis. After full articles were read, 13 were excluded by the eligibility criteria and one due to methodological quality; therefore, only fours articles remained: two retrospective and two randomized prospective studies. Data were collected, analyzed and organized in tables. CONCLUSION: Both interproximal wear and mandibular incisor extraction are effective in treating Class I malocclusion in permanent dentition with moderate anterior lower crowding and pleasant facial profile. There is scant evidence to determine the best treatment option for each case. Clinical decision should be made on an individual basis by taking into account dental characteristics, crowding, dental and oral health, patient's expectations and the use of set-up models. .


OBJETIVO: determinar, por meio de uma revisão sistemática, o melhor tratamento entre desgastes interproximais e extração de incisivos para a correção de apinhamento anteroinferior em pacientes Classe I com dentição permanente. MÉTODOS: foram feitas buscas nas bases de dados eletrônicas MEDLINE, Scopus e Web of Science por artigos publicados de janeiro de 1950 até outubro de 2013. Os critérios de inclusão foram estudos que abordassem tratamentos com desgastes interproximais e/ou extração de incisivos inferiores, de casos Classe I com apinhamento anteroinferior na dentição permanente. RESULTADOS: dos 943 artigos encontrados após a remoção dos duplicados, 925 foram excluídos após a leitura dos resumos. Após leitura dos artigos completos, 13 foram excluídos pelos critérios de eligibilidade e um pela qualidade metodológica, restando quatro artigos, sendo dois retrospectivos e dois prospectivos randomizados. Os dados foram coletados, analisados e organizados em tabelas. CONCLUSÕES: tanto o desgaste interproximal quanto a extração de incisivo inferior são tratamentos eficazes em Classe I na dentição permanente, com apinhamento anteroinferior moderado e perfil facial agradável. Há fracas evidências para determinar a escolha do melhor tratamento para cada caso. A decisão clínica deve ser tomada em bases individuais, considerando as características anatômicas dentárias, da severidade do apinhamento, condições de saúde dentária e bucal, expectativas dos pacientes e ensaio em modelos (set-up). .


Subject(s)
Animals , Female , Pregnancy , Maternal Nutritional Physiological Phenomena/physiology , Myocardium/pathology , Obesity/pathology , Blotting, Western , Fibrosis , Heart/embryology , Matrix Metalloproteinase 9/metabolism , Myocardium/metabolism , Obesity/metabolism , Phosphorylation , Reverse Transcriptase Polymerase Chain Reaction , Sheep , Signal Transduction , /metabolism , Transforming Growth Factor beta/metabolism , /metabolism
17.
Braz. oral res. (Online) ; 29(1): 1-7, 2015. tab, ilus
Article in English | LILACS | ID: lil-777194

ABSTRACT

The objective of this study was to assess the influence of cortical thickness and bone density on the insertion torque of a mini-implant (MI) with microthreads. Mini-implants with lengths of 6 and 8 mm in the active part were inserted into synthetic bone blocks (polyurethane resin). The density of these blocks was 20 pounds per cubic foot (pcf), simulating bone marrow, and that of blocks 1, 2, and 3-mm-thick blocks was 40 pcf, simulating cortical bone. Blocks with uniform density of 40 pcf were also used to simulate bone areas of greater density. Insertion torque was quantified with a universal testing machine (EMIC). For both MIs, increasing insertion torque was associated with increasing cortical bone thickness. For the same MI length, significant differences were observed among all assessed groups. The insertion torque of the 6-mm-long MI inserted in a 3-mm-thick cortical bone was equivalent to that of the 8-mm-long MI inserted in a 1-mm-thick cortical bone. MIs inserted in bone blocks of greater density presented insertion torque values almost twice as high as those in other groups. The shorter MI, the lower the insertion torque, and the greater the cortical bone thickness, the greater the insertion torque. To minimize fracture risk, the size of MI should be selected according to the insertion site.


Subject(s)
Humans , Dental Implants , Orthodontic Anchorage Procedures/methods , Torque , Analysis of Variance , Bone Density , Bone and Bones/anatomy & histology , Dental Stress Analysis , Equipment Failure Analysis , Materials Testing , Orthodontic Appliance Design , Orthodontic Anchorage Procedures/instrumentation , Reference Values , Risk Factors , Statistics, Nonparametric , Surface Properties
18.
Dental press j. orthod. (Impr.) ; 19(5): 79-87, Sep-Oct/2014. tab, graf
Article in English | LILACS | ID: lil-727098

ABSTRACT

The aim of this study was to assess by means of cone-beam computed tomography (CBCT) scans the transverse effects on the nasomaxillary complex in patients submitted to rapid maxillary expansion (RME) using Haas expander in comparison to untreated individuals. This prospective controlled clinical study assessed 30 subjects (18 boys and 12 girls) with mixed dentition and during pubertal growth. The treated group was submitted to RME with Haas expander, retention for six months and a six-month follow-up after removal. The control group matched the treated group in terms of age and sex distribution. CBCT scans were taken at treatment onset and one year after the expander was activated. Maxillary first molars (U6) width, right and left U6 angulation, maxillary alveolar width, maxillary basal width, palatal alveolar width, palatal base width, right and left alveolar angulation, palatal area, nasal base width, nasal cavity width and inferior nasal cavity area on the posterior, middle and anterior coronal slices were measured with Dolphin Imaging Software(r) 11.5, except for the first two variables which were performed only on the posterior slice. All transverse dimensions increased significantly (P < 0.05) in the treated group in comparison to the control, except for alveolar angulation and inferior nasal cavity area (P > 0.05). Results suggest that increase of molar, maxillary, palatal and nasal transverse dimensions was stable in comparison to the control group one year after treatment with RME.


OBJETIVO: avaliar, por meio de tomografias computadorizada de feixe cônico (TCFC), as dimensões transversais do complexo nasomaxilar de pacientes submetidos à expansão rápida da maxila (ERM) e sem intervenção. MÉTODOS: este estudo clínico prospectivo e controlado avaliou 30 indivíduos (18 meninos e 12 meninas) durante o período de crescimento puberal e dentição mista. O grupo tratado foi submetido à ERM com expansor de Haas, permanecendo 6 meses em contenção e sendo acompanhados por mais 6 meses após a remoção. O grupo controle foi acompanhado durante o mesmo tempo. Foram realizadas TCFC ao início e um ano após a fase ativa. Com o programa Dolphin Imaging 11.5, a largura entre os primeiros molares superiores (U6), angulação dos U6 direito e esquerdo, largura maxilar alveolar, largura maxilar basal, largura alveolar do palato, largura basal do palato, angulação alveolar direita e esquerda, área palatina, largura da base nasal, largura da cavidade nasal e área da cavidade nasal inferior foram obtidas em cortes coronais posterior, médio e anterior, com exceção das duas primeiras medidas, que foram obtidas apenas no corte coronal posterior. RESULTADOS: todas as medidas foram significativamente (p < 0,05) maiores no grupo da ERM, com exceção da angulação alveolar e da área da cavidade nasal, as quais não foram significativas (p > 0,05) entre os grupos. Os resultados sugerem que, um ano após a ERM, a dimensão transversal na cavidade nasal, maxila, palato e região dos molares são maiores do que em indivíduos não tratados. O protocolo de ERM utilizado foi eficaz na manutenção da dimensão transversal durante período de acompanhamento. .


Subject(s)
Child , Female , Humans , Male , Maxilla/anatomy & histology , Nose/anatomy & histology , Palatal Expansion Technique , Alveolar Process/anatomy & histology , Case-Control Studies , Cephalometry/methods , Cone-Beam Computed Tomography/methods , Dentition, Mixed , Follow-Up Studies , Molar/anatomy & histology , Nasal Cavity/anatomy & histology , Orthodontic Appliance Design , Orthodontic Retainers , Prospective Studies , Puberty , Palatal Expansion Technique/instrumentation , Palate/anatomy & histology
19.
Dental press j. orthod. (Impr.) ; 19(2): 90-95, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-714616

ABSTRACT

Objective: The aim of this study was to validate a method used to assess dental asymmetry, in relation to the skeletal midline, by means of CBCT. Methods: Ten patients who had CBCT scans taken were randomly selected for this study. Five different observers repeated 10 landmarks (x, y and z variables for each) and 12 linear measurements within 10 days. Measurements were taken in both arches to evaluate symmetry of first molars, canines and dental midline in relation to the skeletal midline. Intraclass correlation coefficient (ICC) was carried out to assess intra- and interobserver reliability for landmarks and distances. Average mean difference was also assessed to check measurement errors between observers. Results: ICC landmarks was ≥ 0.9 for 27 (90%) and 25 (83%) variables for intra- and interobserver, respectively. ICC for distances was ≥ 0.9 for 7 (58%) and 5 (42%), respectively. All ICC landmarks for distances were >0.75 for both intra- and interobserver. The mean difference between observers was ≤ 0.6 mm for all the distances. Conclusion: The method used to assess dental asymmetry by means of CBCT is valid. Measurements of molars, canines and dental midline symmetry with the skeletal midline are reproducible and reliable when taken by means of CBCT and by different operators. .


Objetivo: validar um método para avaliar assimetria dentária, em relação à linha média esquelética, usando TCFC. Métodos: dez pacientes que realizaram TCFC foram selecionados aleatoriamente para esse estudo. Cinco diferentes observadores repetiram 10 pontos de referência (com variáveis x, y e z, para cada ponto) e 12 medidas lineares em um intervalo de 10 dias. As medições foram realizadas em ambas as arcadas, para avaliar a simetria de primeiros molares, caninos e linha média dentária, em relação à linha média esquelética. Índice de correlação intraclasse (ICC) foi realizado para verificar a confiabilidade intraobservador e interobservadores para os pontos de referência e distâncias. A diferença média também foi avaliada, para checar os erros de mensuração entre os observadores. Resultados: ICC para os pontos de referência foram ≥ 0,9 para 27 (90%) e 25 (83%) das variáveis para intra- e interobservadores respectivamente. ICC para distâncias foi ≥ 0,9 para 7 (58%) e 5 (42%), respectivamente. Todas as medidas de ICC para distâncias foram > 0,75 para intraobservador e interobservadores. A diferença média entre observadores foi ≤ 0,6mm para todas as distâncias. Conclusão: o método de verificação de assimetria dentária utilizando TCFC é válido. Medições de molares, caninos e linha média dentária com a linha média esquelética são reproduzíveis e confiáveis quando feitas utilizando TCFC, mesmo que por diferentes operadores. .


Subject(s)
Humans , Cephalometry/statistics & numerical data , Cone-Beam Computed Tomography/statistics & numerical data , Malocclusion , Tooth Crown , Anatomic Landmarks , Cuspid , Dental Arch , Image Processing, Computer-Assisted/statistics & numerical data , Incisor , Mandible , Maxilla , Molar , Nasal Bone , Observer Variation , Reproducibility of Results
20.
Dental press j. orthod. (Impr.) ; 17(3): 132-137, May-June 2012. ilus, tab
Article in English | LILACS | ID: lil-646360

ABSTRACT

OBJECTIVE: To evaluate cephalometric changes in tooth and profile position in young adolescent individuals with Class I biprotrusion submitted to orthodontic treatment with extractions of four first premolars. METHODS: Pre and posttreatment lateral cephalometric radiographs from 20 patients with Class I biprotrusion malocclusion were used to evaluate the following measurements: nasolabial angle, distance from lips to E line, distance from lips, incisors, tip of the nose and soft tissue pogonion to Sy line. RESULTS: All measurements showed significant changes after treatment (p<0.05), except the distance from lips and soft tissue pogonion to Sy line. There was a positive correlation between the retraction of incisors and the change of upper and lower lips (0.803/0.925; p<0.001). CONCLUSION: The profile retrusion observed occurred more due to nose growth than to lips retraction. The response from soft tissues to incisors retraction showed a great variability.

SELECTION OF CITATIONS
SEARCH DETAIL